Energy and exergy analysis and multi-criteria optimization of an integrated city gate station with organic Rankine flash cycle and thermoelectric generator

نویسندگانMorteza Saadat-Targhi , Shoaib Khanmohammadi
نشریهApplied Thermal Engineering
نوع مقالهFull Paper
تاریخ انتشار2019
رتبه نشریهISI
نوع نشریهچاپی
کشور محل چاپایران

چکیده مقاله

The current study deals with the thermodynamic modeling, and multi-objective optimization of a pressure reduction station integrated with an organic Rankine flash cycle (ORFC) and a thermoelectric generator (TEG) waste heat recovery system (WHRS). Using the real operating data of a city gate station (CGS), a thermodynamic simulation was developed using EES (Engineering Equation Solver). The exergy analysis as a rigorous method was applied to find the exergy destructive components of the integrated system. Computations indicate that the exergy efficiencies of the indirect water bath heater (IWBH), ORFC condenser and TEG modules are 1.41%, 30.45%, and 16.34%, respectively, which are the lowest asset values among all components.

لینک ثابت مقاله